Category: HyperView

Tips & Tricks: HyperWorks 12.0 BasicFEA

Dev Anand

Dev Anand

Senior Manager - Global Initiatives at Altair India
Dev Anand joined Altair in 2004 and is currently the Senior Manager for Global Initiatives at Altair. He has over 16 years in the PLM industry focusing on global initiatives, business development, global customer support, program management, product design development and people management skills. He holds a Bachelor of Mechanical Engineering Degree from M S Ramaiah Institute of Technology, India, and a Post Graduate Diploma in Business Administration with Operations from Symbiosis, India. He is also Six Sigma Green Belt Certified from General Electric Power Systems, who has been trained to be Project Management Professional from PMI, USA and also attended the Leadership program.
Dev Anand

Latest posts by Dev Anand (see all)

First introduced in 2012, the HyperWorks BasicFEA user profile has been recently updated with the addition of many new features. In this video Erik Larson will highlight some of the key capabilities that allow users from the novice to expert … Read More

Learning Video: Composites Modeling in HyperWorks 12.0

Dev Anand

Dev Anand

Senior Manager - Global Initiatives at Altair India
Dev Anand joined Altair in 2004 and is currently the Senior Manager for Global Initiatives at Altair. He has over 16 years in the PLM industry focusing on global initiatives, business development, global customer support, program management, product design development and people management skills. He holds a Bachelor of Mechanical Engineering Degree from M S Ramaiah Institute of Technology, India, and a Post Graduate Diploma in Business Administration with Operations from Symbiosis, India. He is also Six Sigma Green Belt Certified from General Electric Power Systems, who has been trained to be Project Management Professional from PMI, USA and also attended the Leadership program.
Dev Anand

Latest posts by Dev Anand (see all)

HyperWorks 12.0 provides a comprehensive set of functionalities for modeling of composites. View this short video to learn more about the latest enhancements in Altair’s modeling and visualization products for composites, such as import composites data from CAD, zone to … Read More

Checking and fixing connectivity in beam models

Dev Anand

Dev Anand

Senior Manager - Global Initiatives at Altair India
Dev Anand joined Altair in 2004 and is currently the Senior Manager for Global Initiatives at Altair. He has over 16 years in the PLM industry focusing on global initiatives, business development, global customer support, program management, product design development and people management skills. He holds a Bachelor of Mechanical Engineering Degree from M S Ramaiah Institute of Technology, India, and a Post Graduate Diploma in Business Administration with Operations from Symbiosis, India. He is also Six Sigma Green Belt Certified from General Electric Power Systems, who has been trained to be Project Management Professional from PMI, USA and also attended the Leadership program.
Dev Anand

Latest posts by Dev Anand (see all)

It is always necessary to check and fix any connectivity issues in a 1d beam model to avoid unrealistic results generally, avoid excessive deformation. To do so we must visually inspect the model for any connectivity issues; however this may … Read More

Tips & Tricks: Session File and Report Templates in HyperView

Dev Anand

Dev Anand

Senior Manager - Global Initiatives at Altair India
Dev Anand joined Altair in 2004 and is currently the Senior Manager for Global Initiatives at Altair. He has over 16 years in the PLM industry focusing on global initiatives, business development, global customer support, program management, product design development and people management skills. He holds a Bachelor of Mechanical Engineering Degree from M S Ramaiah Institute of Technology, India, and a Post Graduate Diploma in Business Administration with Operations from Symbiosis, India. He is also Six Sigma Green Belt Certified from General Electric Power Systems, who has been trained to be Project Management Professional from PMI, USA and also attended the Leadership program.
Dev Anand

Latest posts by Dev Anand (see all)

This month’s video will focus on a couple of HyperView capabilities – the session file and the report templates – that could save you a lot of time in post-processing your analysis results, particularly if you run multiple iterations of … Read More

How to change the precision of the value displayed in a note

Dev Anand

Dev Anand

Senior Manager - Global Initiatives at Altair India
Dev Anand joined Altair in 2004 and is currently the Senior Manager for Global Initiatives at Altair. He has over 16 years in the PLM industry focusing on global initiatives, business development, global customer support, program management, product design development and people management skills. He holds a Bachelor of Mechanical Engineering Degree from M S Ramaiah Institute of Technology, India, and a Post Graduate Diploma in Business Administration with Operations from Symbiosis, India. He is also Six Sigma Green Belt Certified from General Electric Power Systems, who has been trained to be Project Management Professional from PMI, USA and also attended the Leadership program.
Dev Anand

Latest posts by Dev Anand (see all)

The purpose of this functionality is to change the precision of the value displayed in a note. Download the Entire Tip>>

Identify the most significant loading condition using Envelope

Dev Anand

Dev Anand

Senior Manager - Global Initiatives at Altair India
Dev Anand joined Altair in 2004 and is currently the Senior Manager for Global Initiatives at Altair. He has over 16 years in the PLM industry focusing on global initiatives, business development, global customer support, program management, product design development and people management skills. He holds a Bachelor of Mechanical Engineering Degree from M S Ramaiah Institute of Technology, India, and a Post Graduate Diploma in Business Administration with Operations from Symbiosis, India. He is also Six Sigma Green Belt Certified from General Electric Power Systems, who has been trained to be Project Management Professional from PMI, USA and also attended the Leadership program.
Dev Anand

Latest posts by Dev Anand (see all)

To identify the most significant loading conditions out of all the selected analysis load steps. The created load step is a summary of all the selected load steps which meet the specified criteria. Download the Entire Tip>>

Cross plot values along a specified node path

Dev Anand

Dev Anand

Senior Manager - Global Initiatives at Altair India
Dev Anand joined Altair in 2004 and is currently the Senior Manager for Global Initiatives at Altair. He has over 16 years in the PLM industry focusing on global initiatives, business development, global customer support, program management, product design development and people management skills. He holds a Bachelor of Mechanical Engineering Degree from M S Ramaiah Institute of Technology, India, and a Post Graduate Diploma in Business Administration with Operations from Symbiosis, India. He is also Six Sigma Green Belt Certified from General Electric Power Systems, who has been trained to be Project Management Professional from PMI, USA and also attended the Leadership program.
Dev Anand

Latest posts by Dev Anand (see all)

The Measure panel in HV is used to plot values along a specified node path. Steps to create Cross plot value along a node path. Load the Vehicle Safety Tools preference file. Contour the required result from the Contour panel … Read More